Circuit Breakers (4x Pack) [Circuit Breakers MP-CB-X4]
4x Single Pole Thermal Circuit Breakers
1x 50A, 2x 150A, 1x 200A
The Series 17 features:
- 48 VDC maximum for 25 - 150 Amp
- 30 VDC maximum for 175 - 200 Amp
- Trip-free operation
- Standard Terminations in Surface and Panel Mount (S0 and P0)
- NEW Easy Access Terminations for Surface and Panel Mount (S1, S3, P1,)
- Auto, manual, or switching option
- Visible trip indication
- Available with 1/4” and NEW 3/8” StainlessSteel Terminal Studs and Sems Nuts
- Waterproof
- Ignition-protected
- Improved Robust Design
- Made in the USA
Standard Amp Ratings
The Series 17 is available in ratings of 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 120, 135, 150, 175 and 200 amps.
Maximum Voltage Ratings
Type III: 48 VDC (25 -150A); 30 VDC (175 - 200A)
Type I: 30 VDC (auto-reset)
Operating Temperature Range
-40°C/-40°F to 85°C/185°F
Weight
Panel Mount: 3.1 oz. (88 gm.)
Surface Mount: 4.0 oz. (114 gm.)
Ultimate Trip
Must Hold 100% at 25°C/77°F.
Must Trip at 135% within 1 hour.
Dielectric Strength
1,500VAC Minimum
Interrupt Capacity (25 - 150A), up to
2,500A @ 14VDC (Type III)
1,500A @ 48VDC (Type III)
3,000A @ 30VDC (Type I)
Interrupt Capacity (175 - 200A)
2,500A @ 14VDC (Type III)
1,500A @ 30VDC ( Type I and Type III)
Endurance (25 - 150A)
14VDC @ 100 cycles, 6X rating (Type I & Type III)
28VDC @ 100 cycles, 2X rating (Type III)
30VDC @ 100 cycles, 2X rating (Type I)
48VDC @ 50 cycles, 1.5X rating (Type III)
Endurance (175 - 200A)
14VDC @ 100 cycles, 6X rating (Type I, Type III 175A)14VDC @ 50 cycles, 4X rating (Type III 200 A)
28VDC @ 50 cycles, 2X rating (Type III)
30VDC @ 100 cycles, 2X rating (Type I)
Environmental
Ignition Protected
Compliant to SAE J1171
Ingress Protection
IP67 dust and waterproof rated—protection against
immersion up to 1 meter of water for 30 minutes.
Corrosion
Conforms to Mil-STD-202, Method 101, Test Condition A,
for 96 hours under a 5% salt spray.
Humidity
Conforms to Mil-STD-202, Method 106, for 240 hours at
95% RH.
Shock
Rated to withstand 100g per Mil-STD-202, Method 213,
Test Condition A.
Vibration
Rated to withstand 10g per Mil-STD-204, Test Condition A.
Regulatory Compliance Summary
Interrupt Capacity: SAE J1625, ABYC-E11, UL1077*
Ignition Protected: SAE J1171
Endurance: SAE J1625
Dielectric Strength: UL1077*
Shock, Vibration, Corrosion, Humidity: Mil-STD-202
Dust and Waterproof: IP67
*tested per UL1077 methods