IMPORTANT: Cookies provide a safer experience and are essential to the store's functionality. By clicking or navigating the site, you are agreeing to our use of cookies. Learn more.
50A Circuit Breaker (MP-CB-50)

50A Circuit Breaker [Circuit Breakers MP-CB-50]

50A Single Pole Thermal Circuit Breakers

The Series 17 features:

  • 48 VDC maximum for 25 - 150 Amp
  • 30 VDC maximum for 175 - 200 Amp
  • Trip-free operation
  • Standard Terminations in Surface and Panel Mount (S0 and P0)
  • NEW Easy Access Terminations for Surface and Panel Mount (S1, S3, P1,)
  • Auto, manual, or switching option
  • Visible trip indication
  • Available with 1/4” and NEW 3/8” StainlessSteel Terminal Studs and Sems Nuts
  • Waterproof
  • Ignition-protected
  • Improved Robust Design
  • Made in the USA

Standard Amp Ratings

The Series 17 is available in ratings of 25, 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 120, 135, 150, 175 and 200 amps.

Maximum Voltage Ratings

Type III: 48 VDC (25 -150A); 30 VDC (175 - 200A)
Type I: 30 VDC (auto-reset)

Operating Temperature Range

-40°C/-40°F to 85°C/185°F

Weight

Panel Mount: 3.1 oz. (88 gm.)
Surface Mount: 4.0 oz. (114 gm.)

Ultimate Trip

Must Hold 100% at 25°C/77°F.
Must Trip at 135% within 1 hour.

Dielectric Strength

1,500VAC Minimum

Interrupt Capacity (25 - 150A), up to

2,500A @ 14VDC (Type III)
1,500A @ 48VDC (Type III)
3,000A @ 30VDC (Type I)

Interrupt Capacity (175 - 200A)

2,500A @ 14VDC (Type III)
1,500A @ 30VDC ( Type I and Type III)

Endurance (25 - 150A)

14VDC @ 100 cycles, 6X rating (Type I & Type III)
28VDC @ 100 cycles, 2X rating (Type III)
30VDC @ 100 cycles, 2X rating (Type I)
48VDC @ 50 cycles, 1.5X rating (Type III)

Endurance (175 - 200A)

14VDC @ 100 cycles, 6X rating (Type I, Type III 175A)
14VDC @ 50 cycles, 4X rating (Type III 200 A)
28VDC @ 50 cycles, 2X rating (Type III)
30VDC @ 100 cycles, 2X rating (Type I)

Environmental

Ignition Protected
Compliant to SAE J1171

Ingress Protection

IP67 dust and waterproof rated—protection against
immersion up to 1 meter of water for 30 minutes.

Corrosion

Conforms to Mil-STD-202, Method 101, Test Condition A,
for 96 hours under a 5% salt spray.

Humidity

Conforms to Mil-STD-202, Method 106, for 240 hours at
95% RH.

Shock

Rated to withstand 100g per Mil-STD-202, Method 213,
Test Condition A.

Vibration

Rated to withstand 10g per Mil-STD-204, Test Condition A.

Regulatory Compliance Summary

Interrupt Capacity: SAE J1625, ABYC-E11, UL1077*
Ignition Protected: SAE J1171
Endurance: SAE J1625
Dielectric Strength: UL1077*
Shock, Vibration, Corrosion, Humidity: Mil-STD-202
Dust and Waterproof: IP67
*tested per UL1077 methods


Write a review

Please login or register to review

50A Circuit Breaker

  • 115.17€
  • Ex Tax: 96.78€

Tags: 50a, circuit, breaker, breakers, mechanical, products

Trunk floor compartment auto-illumination module (optional add-on) New
This add-on consists of 2 cables that connect to the Internal DC Out (via Powerpole) and allow the ..
61.88€
Ex Tax: 52.00€
X6-Electromod 2-3 Days
The HALLON Power© X6-ElectroMod is a complete power solution for the BMW X6 series (E71 model). ..
3,403.40€
Ex Tax: 2,860.00€
Wireless ‘Parallel Mode’ module (optional add-on) New
This add-on consists of a wireless receiver and a wireless remote control unit. When installed insi..
71.40€
Ex Tax: 60.00€
Cable connector between:BEP SBB +ve & Fuse#2..
3.26€
Ex Tax: 2.74€
Cable connector between:BEP AB +ve & Fuse#1..
4.45€
Ex Tax: 3.74€
System Panel Complete (unassembled) 2-3 Days
This package contains all five panels required to completely assemble the System Panel.System ..
403.41€
Ex Tax: 339.00€